Sign In | Join Free | My himfr.com
Home > Aluminum Compressed Air Filter >

Installation method of compressed air filter

Hongrijia Depurate Facility Science & Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Installation method of compressed air filter from wholesalers
     
    Buy cheap Installation method of compressed air filter from wholesalers
    • Buy cheap Installation method of compressed air filter from wholesalers
    • Buy cheap Installation method of compressed air filter from wholesalers
    • Buy cheap Installation method of compressed air filter from wholesalers
    • Buy cheap Installation method of compressed air filter from wholesalers
    • Buy cheap Installation method of compressed air filter from wholesalers

    Installation method of compressed air filter

    Ask Lasest Price
    Brand Name : Yuka
    Price : Negotiable
    Delivery Time : 3-7working days
    Payment Terms : L/C,T/T
    Supply Ability : 300,000pcs/month
    • Product Details
    • Company Profile

    Installation method of compressed air filter

    Product Description

    Installation method of Compressed Air Filter

    ①Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.

    ②The Filter Element should be replaced regularly. When replacing the filter element, use an Allen wrench to unscrew the four screws of the lower cover and take out the old filter element from below. Carefully record the replacement time. It is recommended that the working time z should not exceed 8000 hours.

    ③The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;

    ④Different grades of compressed Air Filters can be equipped with electronic drain valves or manual valves according to customer requirements.


    7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
    PFAOAAAXACSARAAR
    As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligibleHigh efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w).High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w)Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w)Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w)Dust particles whose diameter more than 1μm can be removedDust particles whose diameter more than 0.01μm can be removed

    International test and measurement standard ISO12500
    >ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
    parameters are the air inlet oil content and particles size distribution of the solid particles.
    >ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
    >ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
    >ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.

    Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.


    Filtration GradePFAOAAAXACSARAAR
    Size of solid particles(ISO12500-3)5μm1μm0.01μm0.01μm-1μm0.01μm
    Filtration performance of solid particles(ISO12500-3)-99.999+%99.999+%99.999+%99.999+%99.999+%99.999+%
    Filtration performance of oil(ISO12500-1)50%80+%99.9+%99.99+%---
    Residual oil content(ISO12500-1)5mg/m³0.6mg/m³<0.01mg/m³<0.001mg/m³<0.004mg/m³--

    Product Picture

    compressed air water filterCompressed air filter element



    Technical Specification
    The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).For application in other working pressure, please refer to the correction factors.
    ModelPipe sizeFlow ratesDimension (mm)
    L/Sm³/minscfmW(Width)D(Depth)H (Height)ABC(clearance for housing)
    YFB010RC1/2"16.71.035.5967925229223118
    YFB020RC3/4"25.01.553.0967925229223118
    YFB030RC3/4"30.01.863.6967928629257153
    YFB040RC1"33.32.071.0967928629257153
    YFB060RC1"60.03.6127.013811135737320208
    YFB070RC1"83.35.0177.013811145837421303
    YFB080RC1-1/2"125.07.5265.013811145837421303
    YFB090RC2"166.710.0353.117414255858500467
    YFB100RC2-1/2"216.713.0459.017414255858500467
    YFB110RC2"283.317.0600.017414283858780794
    YFB120RC2-1/2"316.719.0671.017414283858780794
    YFB130RC3"416.725.0883.022018464574571514
    YFB140RC4"466.728.0989.022018464574571514
    YFB150RC3"683.341.01448.022018490274828764
    YFB160RC4"800.048.01695.022018490274828764
    Technical requirementsMaximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

    PressureBarg12345678910111213141516
    Psig152944597387100116131145160174189203219232
    Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51

    Air compressor filter compressed air filter dryer




    YUKA Package
    Yuka High Grade Compressed Air Filter for Automatic Industry (YF-B090)


    YUKA service
    a. Providing professional consultation, technical support and special solutions
    b. Providing timely feedback on complaints
    c. Providing perfect after sales service and warranty

    Q:Why choose us?
    a. Over 20 years' practical experiences in R&D and manufacturing Compressed air treatment;
    b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
    c. ISO 9001:2015, CE and product follow ISO8573-1;
    d. With Germany Imported high efficiency filtration Test Instrument;
    e.All goods had been 100% test before dispatched.


    FAQ
    Q1. What kind of your company is it?
    We're the manufacturer integrated with R&D, production and sales.

    Q2. How about your technical conditions and production capability?
    Complete process documents and equipment, mass production.

    Q3. What is the delivery time?
    Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.

    Q4. Do you have a warranty?
    Yes, for filter, it is 1 year normally.

    Q5. Can you supply customized product?
    Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.


    Quality Installation method of compressed air filter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hongrijia Depurate Facility Science & Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)