Sign In | Join Free | My himfr.com
Home > Aluminum Compressed Air Filter >

Compressed Air Filter for Removal Odor

Hongrijia Depurate Facility Science & Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Compressed Air Filter for Removal Odor from wholesalers
     
    Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers
    • Buy cheap Compressed Air Filter for Removal Odor from wholesalers

    Compressed Air Filter for Removal Odor

    Ask Lasest Price
    Brand Name : Yuka
    Price : Negotiable
    Delivery Time : 3-7working days
    Payment Terms : L/C,T/T
    Supply Ability : 300,000pcs/month
    • Product Details
    • Company Profile

    Compressed Air Filter for Removal Odor

    Product Description

    Product Selling Point

    7 Layers for Filter Element, fiber glass material, PF/AO/AA/AX with 4000-6000 hours spanlife.
    Meet the standard of ISO8573.1-2010Effectively filter solid particles up to 0.01 microns, suspended oil up to 0.001mg/m³.
    15 years warranty for air filter case, integrate die-casting technology with aluminum alloy material.


    7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR

    PFAOAAAXACSARAAR
    As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligibleHigh efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w).High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w)Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w)Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w)Dust particles whose diameter more than 1μm can be removedDust particles whose diameter more than 0.01μm can be removed

    International test and measurement standard ISO12500

    >ISO 12500 has made clear a general test and definition method for the Compressed Air Filter manufacturers. The main performance
    parameters are the air inlet oil content and particles size distribution of the solid particles.
    >ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
    >ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
    >ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.


    Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
    Filtration GradePFAOAAAXACSARAAR
    Size of solid particles(ISO12500-3)5μm1μm0.01μm0.01μm-1μm0.01μm
    Filtration performance of solid particles(ISO12500-3)-99.999+%99.999+%99.999+%99.999+%99.999+%99.999+%
    Filtration performance of oil(ISO12500-1)50%80+%99.9+%99.99+%---
    Residual oil content(ISO12500-1)5mg/m³0.6mg/m³<0.01mg/m³<0.001mg/m³<0.004mg/m³--

    Feature
    1. Aluminum Alloy material, 15 years serve life for filter housing under working condition from temperature 1.5ºC~80ºC.
    Maxi. Pressure is 1.0Mpa.
    2. 6000~8000 hours serve life for filter element,filtering performance up to 99%
    3. Integrated die-casting filter up to 4 inch, flow rate up to 48m³/min.
    4. Top cap of filter element with diversion fins, which will let the air come inside the filter more smooth, less pressure loss.


    Technical Specification
    The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
    For application in other working pressure, please refer to the correction factors.
    ModelPipe sizeFlow ratesDimension (mm)
    L/Sm3/minscfmW(Width)D(Depth)H(Height)ABC(clearance for housing)
    YF010RC1/2"16.71.035.3967926129198118
    YF020RC3/4"25.01.553.0967926129198118
    YF030RC3/4"30.01.863.6967929529233153
    YF040RC1"33.32.071.0967929529233153
    YF060RC1"60.03.6127.013811140337296208
    YF070RC1"83.35.0177.013811150337396303
    YF080RC1-1/2"125.07.5265.013811150337396303
    YF090RC2"166.710.0353.117414273658607469
    YF100RC2-1/2"216.713.0459.017414273658607469
    YF110RC2"283.317.0600.0174142101658887794
    YF120RC2-1/2"316.719.0671.0174142101658887794
    YF130RC3"416.725.0883.022018479374649514
    YF140RC4"466.728.0989.022018479374649514
    YF150RC3"683.341.01448.0220184105074906764
    YF160RC4"800.048.01695.0220184105074906764
    Technical requirementsMaximum operating pressure: 10 barg Operating temperature: 1.5°C~80°C.