    The Working Principle Of Compressed Air Filter


    Gravity

    In compressed air, oil droplets with particle diameters ranging from 20μm to 50μm will directly gather at the bottom of the filter under the action of gravity. The greater the airflow velocity, the lower the filtration efficiency;


    Inertial collision

    Large-area particles with a diameter greater than 1μm are not consistent with the airflow path. The greater the airflow velocity, the higher the collision rate and the better the effect.


    Direct intercept

    The airflow of particles with a diameter of 1μm to 0.3μm is intercepted and separated by the fiber layer at 1/2 of the Filter Element. The smaller the particle, the lower the interception efficiency.


    Penetration

    Particles with a diameter of less than 0.3μm are too small for liquid versatility. The irregular Brownian motion generated at this time is inconsistent with the air flow path. The smaller the particle, the more intense the Brownian motion and the greater the probability of capturing.


    Filter Type

    Particulate compressed Air Filters are used to remove dust and particles from the air.

    Coalescing filters are used mainly to capture oil and/or moisture that is suspended in the compressed air in very tiny droplets.

    Activated carbon filters remove (oil) odors and vapors.

    Let’s take a look at the different types of air filters and the questions that will help you choose the correct filter.

    ①Assess the requirements of your application. Different industry require different solution.③Any specific micron of filtration performance you required?
    ②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams.
    ④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel)
    ⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment.

    Feature & Benefit
    ① 15 year guaranty for air filter housing under working condition from temperature 1.5ºC~80ºC. Maxi. Pressure is 1.0Mpa.

    6000~8000 hours spanlife for filter element,filtering performance up to 99.99%
    ③ Integrated die-casting filter up to 3 inch, flow rate up to 37.2m³/min.

    ④ Alternative for Domnick Hunter Oil X Plus Series.

    ⑤ Configuration: Differential pressure indicator, sight glass, auto drain.


    Compressed air filter partsAir compressor filter parts


    Filter Element Grade


    Filtration GradeAir filter ELEMENTpre filter ELEMENTcoalescing air filter ELEMENTELEMENTACTIVATED CARBON ELEMENTscustoms air filter ELEMENTair filter parts ELEMENT
    PFAOAAAXACSARAAR
    Particle removal (ISO12500-3)5μm1μm0.01μm0.01μm-1μm0.01μm
    Outlet oil aerosol concentration (ISO12500-1)5mg/m³0.6mg/m³<0.01mg/m³<0.001mg/m³<0.004mg/m³--
    Filtration performance of Particle (ISO12500-3)-99.999+%99.999+%99.999+%99.999+%99.999+%99.999+%
    Filtration performance of (ISO12500-1)50%80+%99.9+%99.99+%---
    Element spanlife6000 hours6000 hours6000 hours6000 hours2000-3000 hours4000-6000 hours4000-6000 hours
    Precede withBefore Refrigerated Air Dryerafter air dryerafter AOafter AAbefore AXafter desiccant dryerafter AR
    Technical Specification
    The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
    For application in other working pressure, please refer to the correction factors.

    ModelPipe sizeFlow ratesDimension (mm)
    L/S/minscfmW(Width)D (Depth)H (Height)ABC(clearance for housing)
    YD017RC1/2"16.71.035.3897924640186118
    YD025RC3/4"25.01.553.0897924640186118
    YD030RC1/2"30.01.863.6897928040220158
    YD035RC3/4"33.32.070.6897928040220158
    YD058RC3/4"46.72.898.912011037755276195
    YD068RC1"60.03.6127.112011037755276195
    YD080RC1"80.04.8169.512011047755377290
    YD145RC1-1/2"120.07.2254.212011047755377290
    YD220RC2"200.012.0423.716215167664566480
    YD260RC2-1/2"233.314.0494.416215167664566480
    YD330RC2"267.216.0564.816215198464875780
    YD360RC2-1/2"317.319.0670.716215198464875780
    YD405RC2-1/2"367.422.0776.620018975778634560
    YD430RC3"467.628.0988.420018975778634560
    YD620RC3"620.037.21313.6200189101278889780
    Technical requirementsMaximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

    PressureBarg1235678910111213141516
    Psig1529447387100116131145160174189203219232
    Correction factor0.380.530.650.850.931.001.071.131.191.231.311.361.411.461.51