Problem in Compressed Air System
There is large amount of water in compressed air system, which will
corrode the pipeline, damage the valves permanently, air cylinders
and pneumatic tools and devices, reduce efficiency of the
after-cooler/ heat exchanger.
TWS Series water separator with high efficiency of separated gas
and water, according the grativity,high speed cyclone rotate to
distinguish the water and water, condensate will be remove by the
auto inner drain. Zero pressure loss and save power and save your
money.
Feature & Advantage
· Protect the coalescing filter from a large amount of liquid
pollution;
· Helps to provide air quality, in line with ISO8573-1:2010, the
international standard for compressed air quality;
· Suitable for all compressed air applications, suitable for all
compressor types;
· Low operating cost, low pressure loss, low life cycle cost;
· All WS series gas-water separators are covered by a 15-year shell
warranty.
Technical Specification
The flow rate below is the treatment capacity of compressed air
under rated working pressure 7 bar g (100psi g).
For the application in other working pressure, please refer to the
correction factors.
Model | Pipe Size | Flow rates | Dimension(mm) | ||||||
L/S | m³/min | cfm | W(Weight) | H(High) | A | B | C (clearance for housing) | ||
TWS009 | RC1/4" | 15.0 | 0.9 | 31.8 | 81 | 197 | 24.6 | 173.9 | 50.5 |
TWS010 | RC3/8" | 25.1 | 1.5 | 53.0 | 81 | 197 | 24.6 | 173.9 | 50.5 |
TWS011 | RC1/2" | 46.8 | 2.8 | 98.8 | 108 | 249 | 30.1 | 220.6 | 53.3 |
TWS012 | RC3/4" | 66.8 | 4.0 | 141.2 | 108 | 249 | 30.1 | 220.6 | 53.3 |
TWS014 | RC3/4" | 86.8 | 5.2 | 183.6 | 108 | 289 | 30.1 | 260.6 | 53.3 |
TWS016 | RC1" | 130.3 | 7.8 | 275.3 | 133 | 332 | 40.7 | 291 | 59.6 |
TWS018 | RC1-1/2" | 175.4 | 10.5 | 370.7 | 133 | 332 | 40.7 | 359.8 | 59.6 |
TWS020 | RC2" | 300.0 | 18.0 | 636.0 | 170 | 617 | 52.92 | 662.97 | 59.6 |
Technical requirements | Maximum operating pressure: 10barg Operating temperature: from 1.5℃ to 80°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Compressed Air Solution