Sign In | Join Free | My himfr.com
Home > Integrated Refrigerated Desiccant Air Dryer >

Integrated Refrigerated & Desiccant Air Dryer Saving Energy

Hongrijia Depurate Facility Science & Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Integrated Refrigerated & Desiccant Air Dryer Saving Energy from wholesalers
     
    Buy cheap Integrated Refrigerated & Desiccant Air Dryer Saving Energy from wholesalers
    • Buy cheap Integrated Refrigerated & Desiccant Air Dryer Saving Energy from wholesalers

    Integrated Refrigerated & Desiccant Air Dryer Saving Energy

    Ask Lasest Price
    Brand Name : Yuka
    Price : Negotiable
    Delivery Time : 3-7working days
    Payment Terms : L/C,T/T
    • Product Details
    • Company Profile

    Integrated Refrigerated & Desiccant Air Dryer Saving Energy

    Product Description

    The working principle of the refrigerated dryer

    The refrigeration dryer uses cooling air to condense the moisture of the humid air and then separate it out of the air to obtain drier air. The following is an analysis of the working principle of the refrigeration dryer as follows:


    The humid, high-temperature compressed air flows into the precooler (for high-temperature type) to dissipate heat and then flows into the heat exchanger to exchange heat with the cold air discharged from the evaporator, reducing the temperature of the compressed air entering the evaporator.


    After the heat exchange, the compressed air flows into the evaporator and exchanges heat with the refrigerant through the heat exchange function of the evaporator. The heat in the compressed air is taken away by the refrigerant. The compressed air is rapidly cooled, and the moisture in the humid air reaches the saturation temperature and quickly condenses. The condensed water is condensed to form water droplets, which are rotated at a high speed through the gas-water separator. The water is separated from the air due to centrifugal force, and the separated water is discharged from the Automatic Drain Valve. The dew point of compressed air pressure after cooling can reach +3 ℃ to +10℃


    Feature & Benefit

    Space saving: integrated design of dryer, filter, gas-water separator and suction dryer, saving space;

    Energy saving: The design of three-in-one aluminum alloy heat exchanger minimizes the process loss of cooling capacity and improves the recycling of cooling capacity. Under the same processing capacity, the total red and green input of the modified model will be reduced by 15-30


    High efficiency: the integrated heat exchanger is equipped with diversion fins, which is the uniform heat exchange of compressed air inside, and the built-in gas-water separation device is equipped with a Stainless Steel Filter screen to separate the moisture more thoroughly.

    Intelligent: Multi-channel temperature and pressure monitoring, real-time display of dew point temperature, automatic recording of accumulated running time, self-diagnosis function, display of corresponding alarm codes, and automatic protection of equipment.


    Environmental protection: Corresponding to the international Montreal agreement, this series of models all use R134a, R410a, R407c environmentally friendly refrigerants, and the degree of damage to the atmosphere is zero, adapting to international market needs;


    Stability: Standard configuration constant pressure expansion valve, standard configuration intelligent temperature control, laboratory test when the temperature reaches 65 , ambient temperature reaches 42 , flammable and stable operation, at the same time with temperature and pressure dual anti-freeze protection When the time is low, the output of the compressor is automatically stopped, and the aluminum plate is used to exchange the stored cooling capacity to provide heat exchange and energy saving, while extending the service life of the equipment.


    Technical Specification

    The following products are suitable for use at 220V 50HZ, 380V 50Hz voltage, other voltages can be customize.

    ModelFlow Rate m³/minDew Point PowerInput power KWConnectionMaxi.Pressure Loss MpaNoiseG.W.(KG)Dimension(MM)
    HLX010-201.2-20220V50Hz0.5RC3/4"≤0.035≤ 75 dB(A)1001200*660*1000
    HLX020-202.2-20220V50Hz0.65RC3/4"≤0.035≤ 75 dB(A)1281200*800*1100
    HLX030-203.6-20220V50Hz0.86RC1"≤0.035≤ 75 dB(A)1861200*800*1100
    HLX060-206.5-20220V50Hz1.39RC1-1/2"≤0.035≤ 75 dB(A)2651500*1000*1100
    HLX080-208.5-20220V50Hz2RC2"≤0.035≤ 75 dB(A)2881500*1000*1600
    HLX100-2011-20220V50Hz2.56RC2"≤0.035≤ 75 dB(A)3681500*1000*1600
    HLX120-2013.5-20220V50Hz2.76RC2"≤0.035≤ 75 dB(A)4501500*1000*1700
    HLX150-2017-20380V50Hz3.13DN50 Flange≤0.035≤ 75 dB(A)5502200*1700*1700
    HLX200-2022-20380V50Hz3.83DN65 Flange≤0.035≤ 75 dB(A)10502200*1700*1800
    HLX010-401.15-40220V50Hz0.5RC3/4"≤0.035≤ 75 dB(A)1001200*660*1000
    HLX020-402-40220V50Hz0.65RC3/4"≤0.035≤ 75 dB(A)1281200*800*1100
    HLX030-403.3-40220V50Hz0.86RC1"≤0.035≤ 75 dB(A)1861200*800*1100
    HLX060-406.2-40220V50Hz1.39RC1-1/2"≤0.035≤ 75 dB(A)2651500*1000*1100
    HLX080-408-40220V50Hz2RC2"≤0.035≤ 75 dB(A)2881500*1000*1600
    HLX100-4011-40220V50Hz2.56RC2"≤0.035≤ 75 dB(A)3681500*1000*1600
    HLX120-4012-40220V50Hz2.76RC2"≤0.035≤ 75 dB(A)4501500*1000*1700
    HLX150-4016-40380V50Hz3.13DN50 Flange≤0.035≤ 75 dB(A)5502200*1700*1700
    HLX200-4020-40380V50Hz3.83DN65 Flange≤0.035≤ 75 dB(A)10502200*1700*1800
    HLX010-701.15-70220V50Hz0.5RC3/4"≤0.035≤ 75 dB(A)1001200*660*1000
    HLX020-702.3-70220V50Hz0.65RC3/4"≤0.035≤ 75 dB(A)1281200*800*1100
    HLX030-703.6-70220V50Hz0.86RC1"≤0.035≤ 75 dB(A)1861200*800*1100
    HLX060-705.6-70220V50Hz1.39RC1-1/2"≤0.035≤ 75 dB(A)2651500*1000*1100
    HLX080-708.5-70220V50Hz2RC2"≤0.035≤ 75 dB(A)2881500*1000*1600
    HLX100-7011-70220V50Hz2.56RC2"≤0.035≤ 75 dB(A)3681500*1000*1600
    HLX120-7013.8-70220V50Hz2.76RC2"≤0.035≤ 75 dB(A)4501500*1000*1700
    HLX150-7017-70380V50Hz3.13DN50 Flange≤0.035≤ 75 dB(A)5502200*1700*1700
    HLX200-7020-70380V50Hz3.83DN65 Flange≤0.035≤ 75 dB(A)10502200*1700*1800

    Working Conditions & Technical Requirements
    Rated ambient temperature: 38 ° C, max.42 ° C.
    Rated inlet temperature: 38 ° C, max. 65 ° C.

    Rated air pressure: 0.7Mpa, max. 1.0Mpa.

    General requirements for compressed air intake conditions

    Solid particle grade: Grade 7 and above specified in GB/T13277.1-2008